Daikin CVXM20A2V1B Installer's Reference Manual page 28

Hide thumbs Also See for CVXM20A2V1B:
Table of Contents

Advertisement

6
|
Unit installation
Installer reference guide
28
Wall-mounted installation
a
b
b
d
c
g
  6‒2 Indoor unit installation drawing: Wall-mounted installation
A
Front view
B
Side view
C
Top view
a
Mounting plate
b
Screw hole 4×
c
Floor
d
Left-back piping hole location
e
Right-back piping hole location
f
Left/right piping hole location
g
Left-bottom piping hole location
h
Right-bottom piping hole location
6 Temporarily secure the mounting plate on the wall.
7 Make sure the mounting plate is level.
8 Mark the centres of the drilling points on the wall.
9 Secure the mounting plate on the wall using 5 screws M4×25L (field supply).
10 Drill a wall hole, depending on which side piping is taken out. See
4
drill a wall
hole" [
11 Open the front panel and remove the front grille (see
4
unit" [
 25]).
12 Remove the slit portions using nippers. See
4
portions" [
 31].
13 If necessary for the skirting board, remove the slit portion on the bottom
frame.
A
b
b
e
C
h
 31].
B
f
c
(mm)
"6.3.2  To
"6.2 Opening the indoor
"6.3.3  To remove the slit
CVXM20+FVXM25~50A2V1B
Split system air conditioners
4P625991-1 – 2020.06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fvxm25a2v1bFvxm35a2v1bFvxm50a2v1b

Table of Contents