Daikin Air Conditioner Installation Manual
Hide thumbs Also See for Air Conditioner:

Advertisement

DAIKIN AIR CONDITIONER
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into DANGER, WARNING and CAUTION. Be sure to follow all the
precautions below: they are all important for ensuring safety.
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION
Failure to follow any of CAUTION may in some cases result in grave consequences.
• The following safety symbols are used throughout this manual:
Be sure to observe this instruction.
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.
DANGER
• Refrigerant gas is heavier than air and replaces oxygen. A massive leak could lead to oxygen depletion, especially
in basements, and an asphyxiation hazard could occur leading to serious injury or death.
• If the refrigerant gas leaks during installation, ventilate the area immediately.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device. Exposure to this gas could cause severe injury or death.
• After completing the installation work, check that the refrigerant gas does not leak.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device. Exposure to this gas could cause severe injury or death.
• Do not ground units to water pipes, telephone wires or lightning rods because incomplete grounding could cause a severe shock hazard
resulting in severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death.
• Safely dispose of the packing materials.
apart and throw away plastic packaging bags so that children will not play with them. Children playing with plastic bags face the danger of death by suffocation.
• Do not install unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death.
• Do not ground units to telephone wires or lightning rods because lightning strikes could cause a severe shock hazard resulting in
severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death.
WARNING
• Installation should be left to the authorized dealer or another trained professional.
Improper installation may cause water leakage, electrical shock, fire, or equipment damage.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, fire or equipment damage.
• Be sure to use the supplied or exact specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, fire or equipment damage.
• Install the air conditioner on a solid base that is level and can support the weight of the unit.
An inadequate base or incomplete installation may cause injury or equipment damage in the event the unit falls off the base or comes loose.
• Electrical work should be carried out in accordance with the installation manual and the national, state and local electrical wiring codes.
Insufficient capacity or incomplete electrical work may cause electrical shock, fire or equipment damage.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance. Follow all appropriate electrical codes.
• For wiring, use a wire or cable long enough to cover the entire distance with no splices if possible. Do not use an extension cord. Do not put other
loads on the power supply. Use a only a separate dedicated power circuit.
• Use the specified types of wires for electrical connections between the indoor and outdoor units. Follow all state and local electrical codes.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating, fire or equipment damage.
• After connecting all wiring be sure to shape the cables so that they do not put undue stress on the electrical covers, panels or terminals.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock,fire or equipment damage.
• When installing or relocating the system, be sure to keep the refrigerant circuit free from all substances other than the specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise which may result in rupture, resulting in injury.)
3P232733-1A M08B058A

Safety Precautions

Be sure to establish an earth
connection.
Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries. Tear
(Failure to do so may cause abnormal heat, electric shock, fire or equipment damage.)
Two-dimensional bar code
is a code for manufacturing.
Never attempt.

Advertisement

Table of Contents
loading

Summary of Contents for Daikin Air Conditioner

  • Page 1: Safety Precautions

    Use of other parts may cause the unit to come to lose, water leakage, electrical shock, fire or equipment damage. • Install the air conditioner on a solid base that is level and can support the weight of the unit.
  • Page 2: Precautions For Selecting The Location

    (Noises may be heard even if they are more than 10 feet away depending on radio wave conditions.) 8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner.
  • Page 3: Precautions On Installation

    Precautions on Installation • Ensure the strength and level of the installation will not cause any operating vibration or noise after installed. • In accordance with the foundation drawing, fix the unit securely by means of the foundation bolts. (Prepare four sets of 3/8”...
  • Page 4: Outdoor Unit Installation

    Outdoor Unit Installation (1) Installing Outdoor Unit 1) When installing the outdoor unit, refer to “Precautions for Selecting the Location” and the “Outdoor Unit Installation Drawings.” 2) If drain work is necessary, follow the procedures below. Drain Work 1) Use drain plug for drainage. Drain-water hole 2) If the drain port is covered by a mounting base or floor surface, place additional foot bases of at least 1-1/4”...
  • Page 5 Outdoor Unit Installation (2) Purging Air and Checking for Gas Leakage • When the piping work is completed, it is necessary to purge the air and check for gas leakage. WARNING 1) Do not place any substance other than the specified refrigerant (R410A) into the refrigeration cycle. 2) When a refrigerant gas leak occurs, ventilate the room as soon and as much as possible.
  • Page 6: Pump Down Operation

    Outdoor Unit Installation (3) Refilling The Refrigerant Filling a cylinder with an Filling other cylinders Check the type of refrigerant to be used on the machine attached siphon nameplate. Turn the cylinder Stand the cylinder upright when filling. upside-down when Precautions when adding R410A There is a siphon pipe inside, filling.
  • Page 7 Wiring WARNING 1) Do not use spliced wires, stranded wires, extension cords, or starburst connections, as they may cause overheating, electrical shock, or fire. Follow all Local, and State electrical codes. 2) Do not use locally purchased electrical parts inside the product. (Do not overload the circuit by adding drain pump or other electrical equipment to unit terminals.) Doing so may cause electric shock or fire.
  • Page 8 • The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for some time after installation, shut off the circuit breaker to eliminate unnecessary power consumption.

Table of Contents