Daikin Perfera CVXM20A2V1B Operation Manual

Daikin Perfera CVXM20A2V1B Operation Manual

Hide thumbs Also See for Perfera CVXM20A2V1B:
Table of Contents

Advertisement

Operation manual
Split system air conditioners
CVXM20A2V1B
FVXM25A2V1B
Operation manual
FVXM35A2V1B
English
Split system air conditioners
FVXM50A2V1B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Perfera CVXM20A2V1B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin Perfera CVXM20A2V1B

  • Page 1 Operation manual Split system air conditioners CVXM20A2V1B FVXM25A2V1B Operation manual FVXM35A2V1B English Split system air conditioners FVXM50A2V1B...
  • Page 2: Table Of Contents

    Latest revisions of the supplied documentation may be available on 5.8.3 To start/stop Econo and Outdoor unit quiet operation the regional Daikin website or via your installer. Flash Streamer (air cleaning) operation ........11 5.9.1 To start/stop Flash Streamer (air cleaning) operation. 11 The original documentation is written in English.
  • Page 3: Instructions For Safe Operation

    2 User safety instructions of experience and knowledge can only Instructions for safe operation use this appliance if they have been WARNING: MILDLY FLAMMABLE given supervision or instruction MATERIAL concerning the use of the appliance by The refrigerant inside this unit is mildly a person responsible for their safety.
  • Page 4 2 User safety instructions WARNING WARNING Do NOT place objects below the indoor The appliance shall be stored in a and/or outdoor unit that may get wet. room without continuously operating Otherwise condensation on the unit or ignition sources (example: open refrigerant pipes, air filter dirt or drain flames, an operating gas appliance or blockage may cause dripping, and...
  • Page 5: About The System 5

    Contact your dealer. Outlook of the Daikin eye may be negatively affected if the protection foil was not removed. Remove the protection foil if it wasn’t removed ▪ In case of accidental refrigerant leaks, make sure there during the installation.
  • Page 6: About The User Interface

    4 Before operation Before operation To turn on the power supply 1 Turn the circuit breaker on. To insert the batteries About the user interface The batteries will last for about 1 year. ▪ Direct sunlight. Do NOT expose the user interface to direct 1 Remove the front cover.
  • Page 7: To Set The Brightness Of The Indoor Unit Display

    5 Operation Result: blinks. Condensation and water dripping might occur if the unit runs outside its operation range. In combination with outdoor unit RXTP25+35 Cooling and Heating (a)(b) drying 4 Press to set the correct time. Outdoor temperature –10~46°C DB –25~24°C DB Note: Holding down increases or decreases the time –25~18°C WB...
  • Page 8: To Start/Stop Operation Mode And To Set The Temperature

    When the flap is swinging and you move it forcibly by hand, the mechanism will break. Result: is displayed on the LCD. The Daikin eye indication lamp changes colour according to the operation. See ▪ Be careful when adjusting the louvers. Inside the air lamp" [ 4  5].
  • Page 9: Air Outlet Selection

    5 Operation 5.5.1 To set automatic air outlet selection or INFORMATION top air outlet only When the unit is installed in a corner of a room, the direction of the louvers should be facing away from the Prerequisite: The default setting is automatic air outlet selection. wall.
  • Page 10: Powerful And Heat Plus Operation

    5 Operation Powerful and Heat plus operation Econo and Outdoor unit quiet operation 5.7.1 Powerful operation 5.8.1 Econo operation This operation quickly maximizes the cooling/heating effect in any operation mode. You can get the maximum capacity. This is a function which enables efficient operation by limiting the maximum power consumption value.
  • Page 11: Flash Streamer (Air Cleaning) Operation

    Result: The set time and disappear from the LCD. and the the user interface LCD). day of the week are displayed on the LCD. The Daikin eye stops 1 Press lighting orange. Result: is displayed on the LCD and the air in the room is To start/stop ON timer operation cleaned when the unit is operating.
  • Page 12: Weekly Timer Operation

    LCD. INFORMATION The Daikin eye lights orange. The time displayed on the LCD will automatically count down by 1 hour for every hour that passes. The clock MUST be set correctly before using any timer clock" [ 4  6].
  • Page 13: To Copy Reservations

    Result: The temperature and time are set for the ON timer. The 2 Press to select the day of the week and reservation time is set for the OFF timer. The Daikin eye lights orange. number to be confirmed and check the reservation details. Result: A new reservation screen will appear.
  • Page 14: Wireless Lan Connection

    3 Check the Daikin eye. ▪ Internet line and communication device, such as a modem, router, etc. ▪ Wireless LAN access point ▪ Installed free Daikin Residential Controller application 5.12.1 Precautions when using the wireless LAN Do NOT use near: ▪...
  • Page 15: Energy Saving And Optimum Operation

    1  minute. Refer to the manual of your communication device. If you want to turn off the wireless connection function: Result: If the connection was successful, the Daikin eye colour alternates between blue and partly green. 1 On the home screen, press for at least 5 seconds while the...
  • Page 16: Maintenance And Service

    7 Maintenance and service CAUTION WARNING Do NOT operate the system when using a room The refrigerant inside the unit is mildly flammable, but fumigation-type insecticide. Chemicals could collect in the normally does NOT leak. If the refrigerant leaks in the unit, and endanger the health of people who are room and comes in contact with fire from a burner, a hypersensitive to chemicals.
  • Page 17: To Clean The Indoor Unit And User Interface

    7 Maintenance and service To clean the indoor unit and user interface WARNING Improper detergents or cleaning procedure may cause damage on plastic components or water leakage. Splashed detergent on electric components, such as motors, may cause failure, smoke or ignition. NOTICE 3 Remove the front panel.
  • Page 18: To Remove The Filters

    7 Maintenance and service To remove the filters To clean the titanium apatite deodorising filter 1 Remove the front panel. Refer to "7.3  To clean the front panel" [ 4  17]. INFORMATION 2 Carefully remove the air filter tabs from the claws (a) on the Clean the filter with water every 6 months.
  • Page 19: To Re-Install The Front Panel

    Turn OFF the power well. supply. To re-install the front panel The Daikin eye flashes and you can Notify your installer and check the error code by the user report the error code. 1 Insert the front panel into the grooves of the unit (3 places) and interface.
  • Page 20 3P477071-2F 2020.06 Verantwortung für Energie und Umwelt...

This manual is also suitable for:

Perfera fvxm25a2v1bPerfera fvxm35a2v1bPerfera fvxm50a2v1bCvxm20a2v1bFvxm25a2v1bFvxm35a2v1b ... Show all

Table of Contents