Summary of Contents for Daikin Perfera CVXM20A2V1B
Page 1
Operation manual Split system air conditioners CVXM20A2V1B FVXM25A2V1B Operation manual FVXM35A2V1B English Split system air conditioners FVXM50A2V1B...
Latest revisions of the supplied documentation may be available on 5.8.3 To start/stop Econo and Outdoor unit quiet operation the regional Daikin website or via your installer. Flash Streamer (air cleaning) operation ........11 5.9.1 To start/stop Flash Streamer (air cleaning) operation. 11 The original documentation is written in English.
2 User safety instructions of experience and knowledge can only Instructions for safe operation use this appliance if they have been WARNING: MILDLY FLAMMABLE given supervision or instruction MATERIAL concerning the use of the appliance by The refrigerant inside this unit is mildly a person responsible for their safety.
Page 4
2 User safety instructions WARNING WARNING Do NOT place objects below the indoor The appliance shall be stored in a and/or outdoor unit that may get wet. room without continuously operating Otherwise condensation on the unit or ignition sources (example: open refrigerant pipes, air filter dirt or drain flames, an operating gas appliance or blockage may cause dripping, and...
Contact your dealer. Outlook of the Daikin eye may be negatively affected if the protection foil was not removed. Remove the protection foil if it wasn’t removed ▪ In case of accidental refrigerant leaks, make sure there during the installation.
4 Before operation Before operation To turn on the power supply 1 Turn the circuit breaker on. To insert the batteries About the user interface The batteries will last for about 1 year. ▪ Direct sunlight. Do NOT expose the user interface to direct 1 Remove the front cover.
5 Operation Result: blinks. Condensation and water dripping might occur if the unit runs outside its operation range. In combination with outdoor unit RXTP25+35 Cooling and Heating (a)(b) drying 4 Press to set the correct time. Outdoor temperature –10~46°C DB –25~24°C DB Note: Holding down increases or decreases the time –25~18°C WB...
When the flap is swinging and you move it forcibly by hand, the mechanism will break. Result: is displayed on the LCD. The Daikin eye indication lamp changes colour according to the operation. See ▪ Be careful when adjusting the louvers. Inside the air lamp" [ 4 5].
5 Operation 5.5.1 To set automatic air outlet selection or INFORMATION top air outlet only When the unit is installed in a corner of a room, the direction of the louvers should be facing away from the Prerequisite: The default setting is automatic air outlet selection. wall.
5 Operation Powerful and Heat plus operation Econo and Outdoor unit quiet operation 5.7.1 Powerful operation 5.8.1 Econo operation This operation quickly maximizes the cooling/heating effect in any operation mode. You can get the maximum capacity. This is a function which enables efficient operation by limiting the maximum power consumption value.
Result: The set time and disappear from the LCD. and the the user interface LCD). day of the week are displayed on the LCD. The Daikin eye stops 1 Press lighting orange. Result: is displayed on the LCD and the air in the room is To start/stop ON timer operation cleaned when the unit is operating.
LCD. INFORMATION The Daikin eye lights orange. The time displayed on the LCD will automatically count down by 1 hour for every hour that passes. The clock MUST be set correctly before using any timer clock" [ 4 6].
Result: The temperature and time are set for the ON timer. The 2 Press to select the day of the week and reservation time is set for the OFF timer. The Daikin eye lights orange. number to be confirmed and check the reservation details. Result: A new reservation screen will appear.
3 Check the Daikin eye. ▪ Internet line and communication device, such as a modem, router, etc. ▪ Wireless LAN access point ▪ Installed free Daikin Residential Controller application 5.12.1 Precautions when using the wireless LAN Do NOT use near: ▪...
1 minute. Refer to the manual of your communication device. If you want to turn off the wireless connection function: Result: If the connection was successful, the Daikin eye colour alternates between blue and partly green. 1 On the home screen, press for at least 5 seconds while the...
7 Maintenance and service CAUTION WARNING Do NOT operate the system when using a room The refrigerant inside the unit is mildly flammable, but fumigation-type insecticide. Chemicals could collect in the normally does NOT leak. If the refrigerant leaks in the unit, and endanger the health of people who are room and comes in contact with fire from a burner, a hypersensitive to chemicals.
7 Maintenance and service To clean the indoor unit and user interface WARNING Improper detergents or cleaning procedure may cause damage on plastic components or water leakage. Splashed detergent on electric components, such as motors, may cause failure, smoke or ignition. NOTICE 3 Remove the front panel.
7 Maintenance and service To remove the filters To clean the titanium apatite deodorising filter 1 Remove the front panel. Refer to "7.3 To clean the front panel" [ 4 17]. INFORMATION 2 Carefully remove the air filter tabs from the claws (a) on the Clean the filter with water every 6 months.
Turn OFF the power well. supply. To re-install the front panel The Daikin eye flashes and you can Notify your installer and check the error code by the user report the error code. 1 Insert the front panel into the grooves of the unit (3 places) and interface.
Page 20
3P477071-2F 2020.06 Verantwortung für Energie und Umwelt...
Need help?
Do you have a question about the Perfera CVXM20A2V1B and is the answer not in the manual?
Questions and answers