Specific installer safety instructions
3 Specific installer safety instructions
Installer reference guide
16
Always observe the following safety instructions and regulations.
Unit installation (see
"6 Unit
WARNING
The appliance shall be stored in a room without continuously operating ignition
sources (example: open flames, an operating gas appliance or an operating electric
heater).
CAUTION
For walls containing a metal frame or a metal board, use a wall embedded pipe and
wall cover in the feed-through hole to prevent possible heat, electrical shock, or fire.
Piping installation (see
DANGER: RISK OF BURNING/SCALDING
CAUTION
▪
Use the flare nut fixed to the unit.
▪
To prevent gas leakage, apply refrigeration oil only to the inside of the flare. Use
refrigeration oil for R32.
▪
Do NOT reuse joints.
CAUTION
▪
Do NOT use mineral oil on flared part.
▪
NEVER install a drier to this R32 unit to guarantee its lifetime. The drying material
may dissolve and damage the system.
CAUTION
▪
Incomplete flaring may cause refrigerant gas leakage.
▪
Do NOT re-use flares. Use new flares to prevent refrigerant gas leakage.
▪
Use flare nuts that are included with the unit. Using different flare nuts may
cause refrigerant gas leakage.
Electrical installation (see
DANGER: RISK OF ELECTROCUTION
WARNING
▪
All wiring MUST be performed by an authorised electrician and MUST comply
with the applicable legislation.
▪
Make electrical connections to the fixed wiring.
▪
All components procured on-site and all electrical construction MUST comply
with the applicable legislation.
4
installation" [
23])
4
"7 Piping
installation" [
"8 Electrical
installation" [
35])
4
40])
CVXM20+FVXM25~50A2V1B
Split system air conditioners
4P625991-1 – 2020.06