Installation manual Split system air conditioners CVXM20A2V1B FVXM25A2V1B FVXM35A2V1B Installation manual FVXM50A2V1B English Split system air conditioners...
To re-install the front grille .......... 11 Daikin website (publicly accessible). 8.2.3 To re-install the front panel ......... 11 ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). 9 Commissioning To perform a test run..............11 9.1.1...
3 About the box CAUTION WARNING For walls containing a metal frame or a metal board, use a Use an all-pole disconnection type breaker with at least wall embedded pipe and wall cover in the feed-through 3 mm between the contact point gaps that provide full hole to prevent possible heat, electrical shock, or fire.
INFORMATION INFORMATION The sound pressure level is less than 70 dBA. ▪ Daikin Industries Czech Republic s.r.o. declares that the radio equipment type inside of this unit is in ▪ Spacing. Mind the following requirements: compliance with Directive 2014/53/EU.
5 Unit installation 3 Unhook the 2 tabs on the electrical wiring box cover and remove it. 3 Remove the front panel. 5.2.2 To remove the front grille 1 Remove the front panel. See "5.2.1 To remove the front Screw Wiring box cover panel" [ 4 4].
Page 6
5 Unit installation 1 Drill a wall hole, depending on which side piping is taken out. hole" [ 4 7]. "5.3.2 To drill a wall 2 Open the front panel and remove the front grille (see unit" [ 4 4]). "5.2 Opening the indoor 3 Remove the slit portions using nippers.
5 Unit installation Half-concealed installation 5.3.2 To drill a wall hole CAUTION For walls containing a metal frame or a metal board, use a wall embedded pipe and wall cover in the feed-through hole to prevent possible heat, electrical shock, or fire. NOTICE Be sure to seal the gaps around the pipes with sealing material (field supply), in order to prevent water leakage.
5 Unit installation 2 Remove an burrs along the cut section using a half round needle file. 1× 5.3.4 To provide drainage Make sure condensation water can be evacuated properly. This Drain pan Drain socket involves: Drain hose (accessory) ▪ General guidelines Screw (accessory) leaks" [ 4 8]).
6 Piping installation Connecting the refrigerant piping Piping installation DANGER: RISK OF BURNING/SCALDING Preparing refrigerant piping 6.2.1 To connect the refrigerant piping to the 6.1.1 Refrigerant piping requirements indoor unit NOTICE WARNING: MILDLY FLAMMABLE MATERIAL The piping and other pressure-containing parts shall be The refrigerant inside this unit is mildly flammable.
8 Finishing the indoor unit installation WARNING To connect optional accessories Do NOT connect the power supply to the indoor unit. This (wired user interface, central user could result in electrical shock or fire. interface, wireless adapter, etc.) WARNING 1 Remove the electrical wiring box cover. See "5.2 ...
▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). 3 Push on the sides of the front panel to make sure the front panel is securely fixed.
11 Technical data 11.1 Wiring diagram Symbol Meaning Coil Reactor 11.1.1 Unified wiring diagram legend Stepper motor For applied parts and numbering, refer to the wiring diagram on the Compressor motor unit. Part numbering is by Arabic numbers in ascending order for each part and is represented in the overview below by "*"...
Page 16
3P477070-2H 2020.06 Verantwortung für Energie und Umwelt...