operation

Note: It is recommended to have the engine running to maintain the minimum required voltage of 12.75V DC.
The leveling system should only be operated under the following conditions:
4.
The coach is parked on a reasonably level surface.
5.
The coach "PARKING BRAKE" is engaged.
6.
The coach transmission should be in the park position.
7.
Make sure all persons, pets and property are clear of the coach while LCI4A3LCD Hydraulic Leveling
system is in operation.
After starting the automatic leveling cycle, it is important to avoid movement in the coach until the
coach is level and the green LeD light illuminates in the center of the touchpad. Failure to remain
still during the leveling cycle could have an effect on the performance of the leveling system.

Selecting A Campsite

When the coach is parked on an excessive slope, the leveling requirements may exceed the jack lift stroke
capability. If the coach is parked on an excessive slope, the coach should be moved to a more level surface
before the leveling system is deployed. "Excess Angle" will appear on the LCD screen if the coach is 3.5
degrees or more out of level front-to-rear, or side-to-side.
While utilizing leveling blocks and jack pads, all coach wheels MUSt Not leave the ground during
leveling. Lifting all the wheels off the ground creates a condition where severe property damage,

Zero Point Calibration

Note: Zero Point Calibration may have been pre-set by the OEM. Verify if Zero Point has already been set.
If not, then recalibration for Zero Point must be performed.
Before auto-leveling features are available, the Zero Point MUSt be set. This is the reference point that the
system will return to when an auto-leveling cycle is initiated.
To set the Zero Point, first run a manual leveling sequence to get the coach to the desired level point. Then
activate the Zero Point configuration mode. This mode is enabled by performing the following sequence:
1.
Turn the touchpad off.
2.
With the touchpad off, perform the following:
A. Press Front (Fig. 1G) five times.
B. Press Rear (Fig. 1J) five times.
3.
At this point, an alarm will sound and the display will read "**ZERO POINT CALIBRATION** ENTER to
Set, POWER to Exit."
4.
Press ENTER (Fig. 1C) to set the Zero Point.
5.
The screen will then display "PLEASE WAIT."
6.
An alarm will sound and the screen will display "ZERO POINT SUCCESSFUL."
7.
The touchpad will then turn off.