7. Install Reader Backplate and (Optional*) Fire Shield or Gasket
a. For fire-rated doors only, install reader backplate and fire shield to door using
two (2) #8-18 x 5/8" Phillips flat head self-drilling screws (Fig. 7a).
b. For exterior doors, install reader backplate and gasket (Fig. 7b using two (2)
#8-18 x 5/8" Phillips flat head self-drilling screws.
c. For non-fire rated interior doors, no fire shield or gasket is required; simply install
backplate using two (2) #8-18 x 5/8" Phillips flat head self-drilling screws.
Reader
Backplate
(2) #8 x 5/8" Phillips flat head
self-drilling screws
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
7) Installation Instructions (Continued)
Fire Plate
Fig. 7a
(for exterior doors)
15
Gasket
Fig. 7b