Alternate Indicator Application Diagram #2 (12/24VDC System)
Connect GREEN_LED input to switch controlled by panel. Shorting GREEN_LED to READER_NEG (Black) with
panel switch will override reader LED to keep it green.
Reader Electronics Requires 12VDC Filtered and Regulated
NOTE:
If your lock is configured with End of Line Resistors, reference
instruction sheet FM for the wiring of RX & DPS outputs.
12/24VDC System
12 Conductor
ElectroLynx Har-
From McKinney
*IMPORTANT: Pin 7 must be tied to earth ground in the access
control panel.
Wiring in accordance with the NEC, ANSI/NFPA 70
Fail secure installations are subject to approval of local AHJ
Fail secure installations shall permit use of Listed panic
hardware to allow emergancy exit from the protected area.
Failure to follow proper ESD safe grounding procedures could
lead to equipment failure.
**UL294, S319, & BHMA A156.25 currently not applicable to Alternate Indicator option
6) Wiring Diagrams (Continued)
QC12 Electric
Hinge From
McKinney
ness
SE LP10 ML20600 Mortise Lock
H
120 VAC
12-24VDC
Input
-
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
**GREEN_LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
10
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
N
G
Power Supply
12VDC
(By Others)
-
+
+
Electrical
(-)
12VDC
(+)
(By Others)
DATA 1
DATA 0
RX (NO)
Use (NC) for
RX (COM)
Lock Relay
Fail Safe
Operation
DPS
DPS
(NO) Fail
Secure
Operation
Panel Circuitry
(NC)
Panel Relay
(NO)
Access
Control
Panel