5. Install Lock Body in Door:
Important: Door must remain open during installation. Use door stop.
a. Feed wires through 1-5/16" diameter hole on INSIDE of door while installing lock body (Fig. 5a).
b. Pull wires through hole while inserting lockbody. DO NOT push wires back into cylinder
hole (Fig. 5b).
c. Install, but do not tighten two #12 x 1" combination screws through lock body (Fig. 5a).
Outside Face
of Door
Fig. 5a
6. Install Inside Mounting Plate
a. Feed lockbody wires through mounting plate (Fig. 6a).
b. Place ground wire eyelet between lower left mounting
plate hole and flat head machine screw when
securing mounting plate to door (Fig. 6a).
c. Insert (2) #8 x 3/8" flat head screws into pre-drilled
1/8" diameter holes (Fig. 6a).
The shorter 3/8" screw
must be used for Step 6c.
7) Installation Instructions (Continued)
(2) #12 x 1"
Do not tighten
Detail
SE LP10 ML20600 Mortise Lock
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
14
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Inside Face
of Door
Fig. 5b
Inside Face
of Door
Reader Backplate
(2) 8-32 x 3/8"
Phillips Flat
Head Self- Drill-
ing Screw
Fig. 6a