8. Install Reader and Trim Bezel:
!
Observe precautions for handling electrostatic sensitive devices.
Ensure reader is powered down when inserting/removing the
harness; do not "hot-plug" (i.e., remove/insert) harness while
reader is powered as it may damage reader.
a. Fit trim bezel around the reader. Ensure access hole in the bezel
aligns with screw hole on reader. The reader should be mounted
so holes face bottom of door (Fig 8b).
b. Align top of reader with top of backplate. Pivot the reader down
until seated. Guide wires as needed to avoid pinching.
c. Secure the reader with (1) #6-32 x 3/8" Phillips or anti-tamper
security torx screw to the mounting plate (Fig 8c).
7) Installation Instructions (Continued)
Fig. 8b
Detail
SE LP10 ML20600 Mortise Lock
Fig. 8c
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
16
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Fig. 8a
Reader
Harness