9. Connector Attachments:
a. Connect 6-pin connector from lock body to
6-pin connector on reader harness (Fig. 9a, b).
b. Connect 2-pin connector from lock body to
2-pin connector on reader harness (Fig. 9a, b).
c. Connect ElectroLynx 4- and 8-pin connectors from the door harness to (black) 4- and 8-pin
connectors of the SE LP10 harness (Fig. 9c).
Carefully tuck connected harnesses into one-inch hole in door.
NOTE: Neatly fold the wires into the remaining space to prevent pinching wires when mounting
inside escutcheon (Fig. 9d).
Do not offset connectors and ensure that they are completely seated.
SE LP10
Harness
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
7) Installation Instructions (Continued)
8-pin
ElectroLynx
Fig. 9c
4-pin
ElectroLynx
Fig. 9a
Fig. 9d