Dc Current Measurement; Ac Current Measurement - AEMC 405 User Manual

Power clamp-on meter
Table of Contents

Advertisement

Find Quality Products Online at:
Specific Specifications in MAX/MIN mode in Voltage
(from 10Hz to 1kHz in AC and AC+DC, and from 0.30V):
Accuracy: add 1% R to the values of the previous table.
Capture of the extreme: approximately 100ms.
Specific Specifications in PEAK mode in voltage
(from 10Hz to 1kHz in AC and AC+DC):
Accuracy: add 1.5% R to the values in the previous table.
PEAK capture time: 1ms min. to 1.5ms max.
4.2.4

DC Current Measurement

Measurement
Range (2)
99.99A
Specified
Measurement Range
Accuracy (2)
± (1% R +10cts)
(zero corrected)
Resolution
Note (1)
The display indicates "+OL" above 3000A and "-OL" below -3000A
in REL mode. The "-" and "+" signs are displayed.
Note (2)
The residual current at zero depends on the remanence. It can be
corrected by the "DC zero" function of the HOLD button.
4.2.5

AC Current Measurement

Measurement
0.15 to
Range (2)
99.99A
Specified
Measurement
Range
Accuracy
± (1% R +10cts)
Resolution
0.01A
Note (1)
The display indicates "OL" above 1500A (in PEAK mode). The "-" and
"+" signs are not managed.
- Bandwidth in AC = 2 kHz
Note (2)
In AC, any value between zero and the min. threshold of the
measurement range (0.15A) is forced to show "----" on the display.
Residual current at zero <150mA.
GlobalTestSupply
www.
0.00 to
100.0 to
999.9A
0 to 100% of the measurement range
± (1% R +3cts)
0.01A
0.1A
100.0 to
999.9A
0 to 100% of the measurement range
± (1% R +3cts)
0.1A
37
1000 to
1500A (1)
1500
± (1.5% R +3cts)
1A
1000A
± (1.5% R +3cts)
1A
.com
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

2139.50

Table of Contents