4 SPECIFICATIONS

4.1

REFERENCE CONDITIONS

Quantities of Influence
Temperature:
Relative humidity:
Supply voltage:
Frequency range of the applied signal:
Sine wave:
Peak factor of the applied alternating signal:
Position of the conductor in the clamp:
Adjacent conductors:
Alternating magnetic field:
Electric field:
4.2

SPECIFICATIONS UNDER THE REFERENCE CONDITIONS

Accuracy is expressed in ± (x% of the reading (R) + y counts (ct)).
4.2.1

DC Voltage Measurement

Measurement Range
0.00 to 99.99V
Specified Measurement
Range
Accuracy
Resolution
Input Impedance
Note (1)
The display indicates "+OL" above + 2000V and "-OL"
below – 2000V, in REL mode. The "-" and "+" signs are managed.
Above 1000V, a repetitive beep indicates that the voltage being
measured is greater than the safety voltage for which the device is
guaranteed. The display indicates "OL".
GlobalTestSupply
www.
Reference Conditions
100.0 to 999.9V
0 to 100% of the measurement range
0.00 to 9.99V
± (1% R +10cts)
10.00 to 99.99V
± (1% R +3cts)
0.01V
0.1V
10MΩ
35
23°C ±2°C
45% to 75%
6.0V ±0.5V
45 to 65Hz
pure
√2
centered
none
none
none
1000V (1)
± (1% R +3cts)
1V