4.2.14 Measurement of Apparent AC Power

Measurement
5 to
Range (2) (4)
9999VA
Specified
1 to 100% of the
Measurement
measurement
Range
range
1000A
Accuracy (3)
± (2% R +10cts)
Resolution
1VA
Note (1) - Display of OL above 1000kVA in single-phase (1000V x 1000A)
- Bandwidth in AC in voltage = 3 kHz, in current = 2 kHz
Notes (2), (3) and (4) of the previous § apply.

4.2.15 Measurement of Apparent AC+DC Power

Measurement
5 to
Range (2) (4)
9999VA
Specified
1 to 100% of the
Measurement
measurement
Range
range
Accuracy (3)
1000A
± (2% R +10cts)
1000 to 1500A
± (2.5% R +10cts)
Resolution
1VA
Note (1) - Display of OL above 1500kVA in single-phase (1000V x 1500A)
- Bandwidth in AC in voltage = 3 kHz, in current = 2 kHz
Notes (2), (3) and (4) of the previous § apply

4.2.16 Measurement of Reactive AC Power

Measurement
5 to
Range (2) (4)
9999 var
Specified
1 to 100% of the
Measurement
measurement range
Range
Accuracy (3)
1000A
(7)
± (2% R +10cts)
Resolution
1 var
Note (1) - Display of OL above 1000 kvar in single-phase (1000V x 1000A)
- Bandwidth in AC in voltage = 3 kHz, in current = 2 kHz
GlobalTestSupply
www.
10.00 to
100.0 to
99.99kVA
999.9kVA
0 to 100%
of the measurement range
1000A
± (2% R +3cts)
10VA
100VA
10.00 to
100.0 to
99.99kVA
999.9kVA
1500kVA (1)
0 to 100%
of the measurement range
1000A
± (2% R +3cts)
1000 to 1500A
± (2.5% R +3cts)
10VA
100VA
10.00 to
100.0 to
99.99 kvar
999.9 kvar
0 to 100%
of the measurement range
1000A
± (2% R +3cts)
10 var
100 var
42
.com
1000kVA (1)
1000VA
1000 to
1000VA
1000 kvar
(1)
1 kvar
sales@GlobalTestSupply.com