8.4.5 Operating Mode „Sequence Shot"
The sequence shot operating mode allows a consecutive carrying out of several, if necessary differently
configured, series shots.
A maximum of 20 series shots can be carried out consecutively and without interruption.
A series shot is defined as per chapter 8.4.4 by the parameters "from column" and "number of columns".
Both parameters for each series shot have to be entered into the columns of the table in subsection ➂
(see also figure 10). Every single step defines an individual series shot.
When a sequence shot is carried out, it will start with step 1 and carry out the series of the previously
defined series shots consecutively and without interruption. Figure 13 shows you the configuration of a
sample sequence shot.
The resulting series of consecutive opening and closing times is also shown below.
Figure 14 – Sample configuration of a sequence shot with four steps and the resulting series of opening and

8.4.6 Operating Mode "Single Shot"

Subsection ➃ (see also figure 10) will be used for configuring the operation mode "single shot". All you
enter here is the duration of the opening time, i.e. how long the spray, pulse or dosing valve will be
open/active for the actual performance of the single shot. The opening time will be entered in ms with
one decimal point. As a single shot stands for a one-time opening/activation of the connected valve, no
more parameter definitions are required for the performance.
8.4.7 Operating Mode „Continuity Shot"
For carrying out the operation mode "continuity shot" no parameters are required. When the continuity
shot is performed, the connected spray, pulse or dosing valve will be opened/activated as long as the
shot is performed. It will be closed/deactivated when the continuity shot is finished.
Page 28 of 37
closing times
Operating Manual WLVCM-BA-10