5.3 Adjusting the Incomplete Device

IMPORTANT
Do not turn the raster-needle locking screw any further counter-clockwise if no more
stops are noticeable while turning it! The maximum needle stroke adjustment has been
reached already.
Further turning will cause the raster-needle locking screw to jump out!!
IMPORTANT
Nozzle and needle can be damaged by wrong handling. Only decrease the material
flow (by a right turn of the regulating screw) if material spills out. Do not turn the regu-
lating screw further to the right after the nozzle is closed!
Standard
The individual material quantity can be adjusted with the needle-stroke regulation (10, 11 or 12).
Functional Principle:
Turn the raster head/regulating spindle to the right:
Turn the raster head/regulating spindle to the left:
Special Design
The amount of material can be regulated via the stroke adjustment of the needle. A left turn of the locking
screw increases the material amount. A fine precision thread affects a needle rise that results in an adjust-
ment of 0.5 mm with each turn of the adjusting knob

5.4 Operating Elements Standard

5.5 Operating Elements Special Design

Regulating screw
Assembly Instructions - Full-Jet Valve VMS-05
Regulating screw
decrease the material quantity
increase the material quantity
Release button
Walther Systemtechnik GmbH – D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de – info@walther-2000.de