Optical Interface O1 - Walther Systemtechnik WLVCM Operating Manual

Walther logic valve controller mini
Table of Contents

Advertisement

6.2.2 Optical Interface O1

The O1 optical interface comes with a total of eight light diodes (se also figure xyz); they indicate the
system statuses of the WLVCM:
LED
Name
1
Error temperature
2
Error current limitation
3
Ready for start
Shot/shot sequence
4
active
Shot/shot sequence
5
finished
6
+24V
7
Operating status
8
Input start
Operating Manual WLVCM-BA-10
Value
Specification
ON
Temperature not within tolerance range
OFF
Temperature within tolerance range
ON
Authorized current for clamp "Valve +" exceeded
OFF
Current at clamp "Valve +" below limit value
ON
WLVCM ready for operation
OFF
WLVCM not ready for operation
ON
Currently an application is carried out
OFF
No application active
ON
Application finished
OFF
Application not finished
ON
Operating voltage 24VDC available
OFF
No / wrong operating voltage available
Active date transfer between WLVCM and configuration
ON
tool
No active data transfer between WLVCM and
OFF
configuration tool
ON
Start signal applied (clamps „Start –„ and „Start +")
OFF
Start signal not applied
Table 9 – Light diodes of the optical interface O1 and their relevance