Summary of Contents for Walther Systemtechnik SMS-13
Page 1
Assembly Instructions Airless-Spray Valve SMS-13 Article Number: S13-…. Figure: Airless-Spray Valve SMS-13 with clamp (optional) NOTE Please read the Assembly Instructions carefully before first using the incomplete device and strictly adhere to the instructions! The incomplete device may only be worked with and worked on by persons who are familiar with the assembly instructions and the current regulations for industrial safety and accident prevention.
Assembly Instructions - Spray Valve SMS-13 Rev. 1.1 Page 3 of 26 EC Declaration of Incorporation in accordance with EU Machinery Directive 2006/42/EU, dated 17 May 2006, Appendix II B We herewith confirm that the below mentioned incomplete device meets the basic requirements for safety and health as stated in EU Machinery Directive 2006/42/EU for its design and construction as well as for the configuration released by us on the market.
GmbH has a guarantee of 12 months under normal European operating conditions on its own parts (spare parts are excluded); or according to the conditions of the manufacturer. This guarantee can only be granted by Walther Systemtechnik GmbH, if: ...
Assembly Instructions - Spray Valve SMS-13 Rev. 1.1 Page 5 of 26 2.4 Correct Use This device is a needle valve and will be used for processing materials which can be sprayed in continuous or intermitting operation. Under no circumstances shall aggressive media such as acids, alkaline solutions, detergents, chemicals or others be sprayed.
The supply with control air (for opening and closing) and material will be performed via three hoses. The airless spray valve SMS-13 is a high precision device with a long, reliable service time if the following instructions are strictly followed.
Assembly Instructions - Spray Valve SMS-13 Rev. 1.1 Page 7 of 26 4.3 Type Label The type label was etched into the casing near the material connection. The serial number is also hammered into this la- bel. 5 Installation and Start-up The valve can be installed in any position.
Danger caused by flammable, harmful fluid. Always follow the safety instructions on the container or the safety data sheet for the fluid. As a norm the Airless-Spray Valve SMS-13 operates with a control air pressure of 6 bar. IMPORTANT In case high material pressures are required, make sure that the accident prevention regulations of the trade associations will be strictly followed! The application can be controlled as intermitting or continuous.
Assembly Instructions - Spray Valve SMS-13 Rev. 1.1 Page 9 of 26 7 Taking out of Service 7.1 Short Interruption A short interruption (15 min and more) will always be followed by a clean-spraying. NOTE Please follow the operating instructions! 7.2 Long-term Interruption...
8 Maintenance and Repair 8.1 General Information The airless spray valves of the SMS-13 series are high-quality precision devices which will not fail if treated correctly and will operate almost maintenance-free. All mobile parts should be regularly oiled and also the threads should be greased when the nozzles are cleaned or exchanged.
Internet www.walther-2000.de 9 Troubleshooting 9.1 General Information IMPORTANT First check all supply lines for connection and serviceability. In case of serious problems that cannot be resolved, please contact the Walther Systemtechnik GmbH customer service. 9.2 Malfunctions: Failure Possible cause Action...
Clamp mounting, complete (OPTIONAL) IMPORTANT Always indicate the inscribed serial numbers when ordering spare parts! 10.2 Wear Parts Kits Wear parts kit complete for SMS-13 (Standard) Consisting of: # Pos. 6 or Pos. 10 (O-ring), 4 each # Pos. 9 (O-ring), 1 each # Pos.