Installing The Battery To The Controller Module - Toshiba nv Series Instruction Manual

Controller unit
Hide thumbs Also See for nv Series:
Table of Contents

Advertisement

nV-Tool Ethernet IP address setting switch
Important
 Set either "172.16.64.**" or "192.168.0.**" of nV-Tool Ethernet IP address by the dip switch
No.5 and No.6.
 You may not specify "0" for "**".
4.2

Installing the Battery to the Controller Module

The controller module is shipped from a plant with a battery attached instead of
being built in. Attach the battery before using it.
See "8.4 Replacing the battery" for the installing procedure.
CAUTION
Name
RSW-0
Upper digits (0 to F) of hexadecimal
converted from the lower 3 digits of
nV-Tool Ethernet IP address
(RSW-0)
RSW-1
Lower digits (0 to F) of hexadecimal
converted from the lower 3 digits of
nV-Tool Ethernet IP address
(RSW-0)
Figure 4-3 nV-Tool Ethernet IP address setting
Mount the battery before using the equipment.
Running RAM operation without battery can cause
an accident and damage on the machine due to
malfunction as the data and programs in memory
are lost.
Replace the battery according to the guidance of the
battery replacement period.
Unified Controller nv series Controller Unit Instruction Manual
4.1 Checking the Switch before Starting
Description
172.16.64.**
192.168.0.**
172.16.64.**
192.168.0.**
Mandatory
41