Wiring The Main Circuit Terminal Block Using Procedure E - YASKAWA HV600 Series Installation & Primary Operation

Ac drive for hvac fan and pump applications
Hide thumbs Also See for HV600 Series:
Table of Contents

Advertisement

A - Cutaway section
B - Use a diagonal-cutting pliers to clip this area for
small wires.
Note:
• Different drive models have different wiring covers.
• Remove only the areas of the wiring cover that apply to the wired terminals. If you remove areas that do not apply to the wired
terminal, the drive will not keep its IP20 protective level.
• Make sure that you hold the cutaway section tightly when you remove pieces of the cutaway section. Pieces of the cutaway
section can fly out and cause injury.
• Remove sharp edges from the wiring cover cutaway section to prevent damage to the wires.
• If you use the wiring cover correctly, but you use wires that are not specified by Yaskawa, the drive will not necessarily keep its
IP20 protective level.
• When you use the recommended gauge for the electrical wires, it is not necessary to attach the wiring cover of the main circuit
power input terminal and the drive output terminal. If you use the applicable gauge for the electrical wires, you must attach the
wiring cover.
7.
Attach the wiring cover and terminal block cover to their initial positions and tighten the screws on the terminal
block cover.
8.
Put the terminal cover back in its initial position.

Wiring the Main Circuit Terminal Block Using Procedure E

Main Circuit Terminal Block Wiring Procedure
1.
Remove the keypad and front cover.
2.
Put the ends of prepared wires through the conduits and into the terminal block, then tighten the terminal
screws to the specified torque.
Note:
When you use terminals - and +1 and these terminals have covers, remove them to install the wire.
YASKAWA TOEPC71061732E HV600 Drive Installation & Primary Operation
Figure 7.23 Clip the Cutaway Section of the Wiring Cover
Figure 7.24 Reattach the Wiring Cover
C - Use a diagonal-cutting pliers to clip this area for
large wires.
7 Electrical Installation
45

Advertisement

Table of Contents
loading

Table of Contents