Performance Characteristics
CHARACTERISTICS
HORIZONTAL DEFLECTION SYSTEM (cont)
Sweep Linearity
(relative to center two
displayed divisions)
POSITION Control Range
Normal Displays
X-Y Displays
X I0 Magnifier
Registration
(X10 to XI)
Variable Control Range
Sweep Length
Delay Time
Delay Control Range
Jitter
Delta Time
Delta Control Range
Performance Requirement not checked in manual
6-6
Table 6-1 (cont)
PERFORMANCE REQUIREMENTS
± 5%.
Sweep Linearity applies over the center eight
divisions. Excludes the first 1/4 division or
25 ns from the start of the magnified sweep
and anything beyond the 100th magnified
division.
Able to move the start of the sweep to the
right of the center vertical graticule; able
to move a time mark corresponding to the
end of the tenth division of an unmagnified
sweep to the left of the center graticule.
At least +13 divisions.3
Expands the normal sweep by ten times around
that portion of the sweep positioned at the
center vertical graticule line.3
0.5 division or less shift.
Continuously variable between calibrated
SEC/DIV settings. Extends both the A and B
sweep time per division by at least a factor
of 2.5.
Greater than 10 divisions.
Less than 0.1 division to 10 times the A
SEC/DIV switch setting. Maximum value does
not exceed end of the A Sweep.
1 part in 20,000, or less, peak-to-peak,
during a two-second time interval.
0 to greater than 9.9 divisions to the right
of setting of DELAY control, but maximum
value does not exceed end of the A Sweep.