Operators Familiarization
C o n fig u re M e n u
The CONFIGURE item allows you to select whether or not to keep the
readout on in the single-sequence trigger mode.
Select CONFIGURE from the SERVICE MENU and answer YES or NO to
each of the displayed questions. Either YES or NO will be underlined to indi­
cate how the instrument is presently configured. After YES or NO is se­
lected, the next configuration choice is displayed. After answering the last
question, the SERVICE MENU display returns. To exit from the CONFIG­
URE menu without answering the remaining question(s), press the END
button or the CLEAR DISPLAY button. The CONFIGURE items are listed as
follows:
Instruments Serial Numbered B020099 or below only have
one menu Item in CONFIGURE: KEEP MENU ON WHEN
MEAS'MT SELECTED?
KEEP MENU ON WHEN M EAS' MT SELECTED? (Factory Settings de­
fault is NO.) Selecting NO clears the measurement menu items from the
display after a measurement function is selected. Measurement cursors
remain displayed. The AUTO TRACKING MENU remains on after a selec­
tion has been made.
Selecting YES allows a measurement menu to remain displayed after a
function is selected. The measurement menu items can be removed at any
time by pressing the CLEAR DISPLAY button once.
PRESET TV TRIG SLOPE FOR -SYNC? (Factory Settings default is
YES.) Selecting YES will cause the trigger slopes to preset to
trig mode is selected, and the configure menu is exited. If NO is selected, a
second question is presented.
PRESET TV TRIG SLOPE FOR +SYNC? (Factory Settings default is NO.)
Selecting YES will cause the trigger slopes to preset to " +" when TV trig
mode is selected, and the configure menu is exited. If NO is selected, the
scope will not use a preset slope when a TV trig mode is selected.