Chapter 2: Installation
Power Supply
NEO Modules Connection (Not Connected to a Network)
Network Connection
30
LTC
CPU BOOT
Open*
600Ω
* Default value
Figure 2-19. DIP Switch Setting Values
The IconMaster main control panel uses one external power supply. (For
redundant power supply operation, two power supply units must be used.)
The DC output from one of the provided power supplies should be connected to
PS1 on the IconMaster control panel. Connect the second, redundant power
supply to PS2.
When you plug in the power supply, the IconMaster control panel buttons will
light up. You may want to verify the IP address and software version for your
system. This function is performed via the Service menu (see the IconMaster
Function Operation and Configuration Manual for instructions).
The IconMaster main control panel can be connected directly to the system's
NEO frame-based modules when the system is not connected to a network. To
do this, connect Ethernet on the main control panel to Ethernet 1 on the
MKE-3901 back module using a crossover (twisted) cable.
The IconMaster main control panel can be connected to a network system. To
do this, connect Ethernet on the IconMaster main control panel directly to a
switch on the network using a straight cable.
Normal*
Failsafe
IconMaster Installation and Configuration Manual