Figure 44: Installing a Single-High, Single-Wide GPIM in an SRX650 Services Gateway
4. Using a Phillips (+) screwdriver, tighten the captive screws on each side of the GPIM faceplate.
5. Insert the appropriate cables into the cable connectors on the GPIM.
6. If necessary, arrange the cables to prevent them from dislodging or developing stress points:
Secure the cable so that it is not supporting its own weight as it hangs to the floor.
Place excess cable out of the way in a neatly coiled loop.
Use fasteners to maintain the shape of the cable loops.
After the STATUS LED light turns green and glows steadily on, the GPIM is online and functioning normally.
See
Figure 45 on page 255
Figure 45: GPIM Example with Hot-Swappable Components
1
Table 103: Hot-Swappable Component Descriptions for GPIMs
Number
Component
1
STATUS LED
and
Table 103 on page 255
2
Description
The STATUS LED has the following indicator colors:
Green and steadily on indicates that the GPIM is functioning normally.
Yellow and steadily on indicates that the GPIM is starting up, running
diagnostics, or going offline.
Red and steadily on indicates that the GPIM has failed.
Off indicates that the GPIM is not powered on, is offline, or is not
configured.
for hot-swappable components and their descriptions.
255