U066
Adjusting the table scanning timing
(Message: Table Timing)
Contents
Adjusts the leading edge timing for the table scanning.
Purpose
Executed if there is a regular error between the leading edges of the copy image and original.
Adjustment
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original and press the [Start] key to make a test copy.
4.Press the [System Menu] key.
5.Select the item to adjust.
Items
Front
6.Press the [◄] [►] keys or the numeric keys to change the counter value.
In the case of the copy example 1, raise the setting value.
In the case of the copy example 2, lower the setting value.
* :When the setting value is increased, the image moves forward, and it moves backward
when the setting value is decreased.
7.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034(6-23) > U065(6-25) > U066
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Adjusts the scanner leading edge margin. -45 to 45
Leading edge registration of the copy image (+1.0/-1.5 mm or less)
Original
Figure 6-8
2S0/2S1/2S2/2S3/2S4/2S5/2SG/2SH/3RA
Setting range
Copy
Copy
example 2
example 1
6-26
Initial
Data
setting
variation
0
0.085
mm

Hide quick links: