The grinding fineness knob is hard
to turn.
The steam does not come out of the
GB
nozzle.
There is not enough milk froth.
The milk froth is too bubbly.
The Auto-Cappuccino accessory
does not suck the milk (accessory
sold separately).
After filling the water tank, the
warning message is still displayed.
The cleaning or descaling programme
will not start.
After emptying the used coffee
collector, the warning message is
still displayed.
After washing the cleaning drawer,
the
warning
displayed.
The power has been cut off during a
cycle.
There is water or coffee underneath
the appliance.
A
message
appears.
message
is
still
"Error
code
XX"
Only change the grinder setting when it is operating.
After switching off your appliance and leaving it to cool:
Make sure the tip of the steam nozzle is properly affixed.
Make sure the air inlet on the steam nozzle is not clogged
at the aerator (if necessary clean the air inlet with the
needle supplied). Empty the tank and remove the Claris
filter. Fill the tank with mineral water high in calcium (>
100 mg/litre or .015oz/gallon), it may take as many as 5 to
10 cycles of steam at 60 seconds each cycle to achieve a
continuous jet of steam. Once you have a continuous jet
of steam you should not have to use this particular type of
water again.
Using the needle supplied unblock the small air inlet at
the top of the nozzle if required.
Use a cold container and very fresh, very cold milk that
has been opened recently.
Try changing the type of milk if this does not work (UHT or
pasteurised).
Check that the two ends of the small stainless steel tube are
fitted correctly into the flexible part of the steam nozzle.
Ensure that the tube immersed in the milk is not blocked.
Check that the flexible tube is not twisted and that it is
correctly fitted into the accessory to avoid any air being
sucked in.
After switching of your appliance and leaving it to cool,
unblock the outlet of the Auto-Cappuccino accessory.
Check that the tank is fitted correctly onto the coffee
machine.
Check that the float at the bottom of the tank moves freely.
Rinse the tank and descale if necessary.
Unplug the appliance for 20 seconds then switch it back
on.
Remove the collector, ensure that it is empty, wait for 6
seconds and fit it back in place.
Check that the collector is pushed in correctly.
Remove the drawer, wait for 6 seconds and fit it back in
place.
Check that the cleaning drawer is pushed in correctly.
The appliance resets itself automatically when the power
is switched back on and is ready for a new cycle.
The drip tray has overflowed: empty it and clean the
cleaning drawer.
Check that the drip tray is fitted correctly.
Do not remove the water tank before the end of the cycle.
Unplug the appliance for 20 seconds, remove the Claris
cartridge and if required, put it back into service.
If the fault persists, note the fault number and contact
ROWENTA Customer Service.