Resetting Procedure
Use a thin rigid tool (a toothpick or a paperclip) to press the RESET button on the
back panel.
Keep the RESET button pressed as long as the front panel LED is shining green
(approx. for 5s).
Release the button as soon as the LED starts flashing yellow quickly. It means
that the configuration in the internal FLASH memory is being deleted. This
operation takes about 50s. Do not disconnect the device from power supply
during this period.
Factory Settings
By default, the parameters have the following factory values:
Parameter Name Default Value
Parameter
dhcpclient
ipaddr
ipmask
defaultgw
pwd
activemode
srvipaddr
srvport
srvpwd
Basic Parameter Settings
Telnet –
Use the integrated Telnet server for basic
use any Telnet Client application, integrated telnet.exe in Microsoft Windows or
putty.exe application downloaded from the Internet, for example. The Telnet server
listens at standard port 23.
When the connection has been established,
number and the current firmware version. Enter the password, which is equal to the
connection authorisation password from the
parameter). The default password is admin.
Telnet Commands to 2N
®
2N
NetSpeaker
Enter LC characters only, separate parameters, if any, with a space and confirm every
row with Enter.
®
2N
TELEKOMUNIKACE a.s., www.2n.cz
®
2N
NetSpeaker
Connection
®
NetSpeaker
can be controlled using the commands included in the table below.
Value
0 (OFF)
192.168.1.100
255.255.255.0
192.168.1.1
admin
0 (Passive mode)
192.168.1.2
6999
admin
®
2N
NetSpeaker
®
2N
NetSpeaker
®
2N
NetSpeaker
settings. For connection,
displays its serial
Server (i.e. pwd
70