Maintenance

Maintenance
Email Notification
Click [Modify Settings] to
change settings.
Click [Send Test Message] to
send a test email to the email
address which has been set.
Syslog
Click [Modify Settings] to
change settings.
TeraStation III iSCSI User Manual
Notification
Select whether using Email notification feature or not.
SMTP Server Address
Enter mail server address in [SMTP Server Address] field.
SMTP Port No.
Enter [SMTP Port No.].
If this is left blank, the standard port number (25) is used. If
[Authentication Type] is set to [Disabled] or [POP before SMTP], then
port 25 is used regardless of the number entered in this field.
Authentication Type
Select from [POP before SMTP], [LOGIN (SMTP-AUTH)], or [CRAM-
MD5(SMTP-AUTH/CRAM-MD5)].
POP3 Server Address
Enter mail server address in[POP3 Server Address] field.
POP3 Port No.
Enter [POP3 Port No.].
If this is left blank, the standard port number (110) is used.
SSL/TLS
When [LOGIN (SMTP-AUTH)] or [CRAM-MD5 (SMTP-AUTH/CRAM-MD5)]
are selected for [Authentication Type], specify either [SSL] or [TLS].
Username
Enter the username for authentication.
Password
Enter the password for authentication.
Subject
Specify the subject line that emails will be sent with. Use alphanumeric
characters only. Do not use multi-byte characters.
Recipient(s)
Enter the email address of the recipient, and click [Add]. You can
register up to 5 email addresses as recipients.
Report
Select the contents for email notifications.
• [HDD Status Report]
• [Fan Failure]
Sends when the fan error is recognized.
• [Disk Error]
Sends when the hard drive error is recognized.
• [System Alert]
Syslog
You may select to send logs to a syslog server. Select [Enable] for [Syslog
Transfer], enter the IP address of the syslog server in [Syslog Server IP
Address] field, and select [Save] to transmit logs to a syslog server.
Sends the condition of the hard drives at the specified time on [HDD
Status Report].
Sends when system is rebooted or shut down, or RAID configuration is
changed.
52