Ups Settings - Buffalo TeraStation III TS-IXL User Manual

Network attached storage iscsi
Hide thumbs Also See for TeraStation III TS-IXL:
Table of Contents

Advertisement

UPS Settings

For best results, plug your TeraStation in to a UPS (Uninterruptible Power Supply). This will protect it from many kinds of
power outages. Connected to a UPS, the TeraStation can be automatically shut down and its data protected. Configure
the following settings to use the TeraStation with a UPS.
1
Connect the UPS to a wall socket.
2
Connect the AC cable of the TeraStation to the UPS.
3
Connect the UPS and the TeraStation with either a USB cable or a serial cable.
4
Turn on the UPS, then turn on the TeraStation.
5
6
Your UPS is now configured.
Notes:
• Consult Buffalo Technology's website (www.buffalotech.com) for compatible UPS units.
• After the TeraStation has automatically shut down because of a power outage, do not turn the TeraStation on
again until normal power is restored. If you do, the TeraStation will run on the UPS's battery, and will not shut down
automatically a second time, even if its battery is running low.
• If [UPS Recovery function] is enabled, the UPS will automatically restart the TeraStation when normal power is restored.
TeraStation III iSCSI User Manual
1 In the Web Admin interface, navigate to [Maintenance] - [Power Manage-
ment] - [UPS Settings].
2 Click [Modify Settings].
1 Configure the desired settings.
If your TeraStation is connected directly to the UPS, select [synchronize
with UPS connected to this TeraStation]. To have the UPS shut down
multiple TeraStations on the same network, select [synchronize with UPS
connected to other TeraStation on the network] and enter the IP address
of the TeraStation that is connected directly to the UPS in the field below.
2 Click [Save].
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Terastation iii ts-rixl

Table of Contents