Errors and Warnings
Displays the current status when changing the settings or formatting drives.
Examples of LCD
SYSTEM Error
E00
MPU No Response
DRAM LINES
E01
DATA Failure
DRAM LINES
E02
ADDRESS Failure
RTC Chip
E03
No RTC Clock
SYSTEM Error
E04
Can't Load Krnl!
WDT
E05
SYSTEM Stopped
TFTP MODE
E06
Lost boot image
HD ALL E07
ALL HD Not Found
UPS
E10
Dependent Mode
SYSTEM I10
TOO HOT!
SYSTEM Error
E11
Fan Failure
SYSTEM Error
E12
Cooling Failure
RAID Error
E13
ARRAYx Error
RAID Arrayx
E14
Can't Mount
HDx Error
E15
Many Bad Sectors
HDx Error
E16
HDx Not Found
TeraStation III iSCSI User Manual
Meaning
The system is not responding. Disconnect power for 10 seconds, then reattach
and boot the TeraStation. If the error persists, contact tech support.
IC error. Contact tech support.
IC error. Contact tech support.
Clock error. Disconnect power for 10 seconds, then reattach and boot the
TeraStation. If the error persists, contact tech support.
The firmware is corrupted. Contact tech support for assistance.
System hung. Disconnect power for 10 seconds, then reattach and boot the
TeraStation. If the error persists, contact tech support.
The firmware is corrupted. Wait for 5 minutes. If "E04" appears on the display,
turn off the unit. Contact tech support for assistance.
Hard disks are not found. If the drives are installed but this message appears,
contact Buffalo's tech support for assistance.
Power outage. The TeraStation is running on UPS battery power and will be shut
down safely.
System temperature is above safe limits. Move the TeraStation to a cooler place.
Do not place anything too close to the TeraStation that might block airflow.
The fan is not spinning. Check for dirt or objects caught in fan. Remove any
debris with tweezers or canned air. If the error persists, contact tech support.
System temperature is above safe limits. Move the TeraStation to a cooler place.
Do not place anything too close to the TeraStation that might block airflow.
An error has occurred in the Xth RAID array. The system will run in degraded
mode if RAID1 or RAID5 is used. For best results, test the drives individually and
replace the defective drive.
The Xth RAID array could not be mounted. Turn off the TeraStation, then reboot
it. If the error persists, rebuild the RAID array. If the error still persists, contact
Buffalo's tech support for assistance.
The bad sectors in the Xth hard drive have become serious. Replace the drive.
Cannot find the Xth hard drive. The Xth hard drive may not be connected or may
be damaged. Check the drive and replace if necessary.