9 Select the conditions to send.
• [HDD Status Report]
• [Fan Failure]
• [Disk Error]
• [System Alert]
10 If you have selected [HDD Status Report] for sending condition, select time to send.
11 Click [Save].
You have configured email alerts.
Examples:
These emails are for example only. Your notification emails may be different.
• This email includes [HDD Status Report]:
TeraStation Status Report: Periodical Report: Information
[TeraStation Information]
TeraStation Name: TS-xxxxx
Time Stamp: 2009/03/23 00:00:01
IP Address: 172.16.37.62
Configuration Screen: http://172.16.37.62/
Continuous operating time: 13:51:57
• This email includes [Disk Error]:
TeraStation Status Report: DISK Error Notification: Failure: Fail to mount a disk
DISK Error Notification
The error occurred on HDD.
The erroneous disk drive: Disk 1
Disk could not be mounted.
• This email includes [Fan Failure]:
TeraStation Status Report: FAN Error Notification: Failure: FAN stopped.
FAN Error Notification
The FAN has stopped.
The internal temperature is now over the threshold. Shut down the system.
System temperature: 52 [
TeraStation III iSCSI User Manual
Sends the condition of the hard drives at specified time.
Sends when the fan error is recognized.
Sends when the hard drive error is recognized.
Sends when the TeraStation is rebooted or shut down, or the RAID configuration is
changed.
]
°C