Detection Zone Test — running the detection zone test for the connected
detectors. The test determines the su cient distance for the detectors to
register alarms.
What is Detection Zone Test
Jeweller — con guring the hub-detector ping interval. The settings determine
how frequently the hub communicates with devices and how quickly the loss
of connection is detected.
Learn more
Detector Ping Interval — the frequency of connected devices polling by
the hub is setting in the range of 12 to 300 s (36 s by default)
Number of undelivered packets to determine connection failure — a
counter of undelivered packets (8 packets by default).
The time before raising the alarm by the communication loss between hub
and device is calculated with the following formula:
Ping interval * (number of undelivered packets + 1 correction packet).
The shorter ping interval (in seconds) means faster delivery of the events
between the hub and the connected devices; however, a short ping interval
reduces the battery life. At the same time, alarms are transmitted immediately
regardless of the ping interval.
We do not recommend reducing the default settings of the ping period and
interval.
Note that the interval limits the maximum number of connected devices: