Henny Penny LVE-102 Operation Manual page 57

Split/full vat open fryer (electric)
Hide thumbs Also See for LVE-102:
Table of Contents

Advertisement

6-2. ERROR CODES
DISPLAY
"E-22"
Heat Error-No Heat
"E-31"
Elements are up
"E-41",
Programming failure
"E-46"
"E-47"
Analog converter chip or 12
volt supply failure
"E-48"
Input system error
"E-54C"
Temperature input error
"E-60"
AIF PC board not
communicating with control
PC board
"E-62A"
Communication Error
"E-70C"
Drain valve jumper wire
missing or disconnected
Aug. 2009
CAUSE
Check power cord and have heat circuit checked
Lower elements back into the vat
Turn switch to OFF, then back to ON; if display shows any
of these error codes, have the controls re-initialized; if error
code persists, have the control board replaced
Turn switch to OFF, then back to ON; if "E-47" persists, have
the I/O board, or the PC board replaced
Turn switch to OFF, then back to ON; have control PC board
replaced if "E-48" persists
Turn switch to OFF, then back to ON; have control PC board
replaced if "E-54C" persists
Turn switch to OFF, then back to ON; if "E-60" persists,
have the 1.5 amp fuse on the AIF PC board checked; have the
connector between the PC boards checked; replace AIF PC
board or control PC board if necessary
1. Press and hold TEMP and INFO buttons until LEVEL 1
2. Enter code 1234 using product buttons.
3. Press TEMP button. FRYER SETUP displays.
4. Press Yes/confirm button.
5. Press INFO button to scroll to OIL QUALITY
6. Press the right FILTER button.
7. Press Yes/confirm button.
8. Press No button twice to exit.
Have the jumper wire checked on the PC board at drain
switch interlock position
CORRECTION
Loose connection. Refer to Service Manual.
Replace control board.
Disable OQM.
ENTER CODE displays.
ENABLED YES/NO displays.
6-4