0_Error; 1_Init; 2_On; 3_Shutdown - probst VM-301-KJ-GREENLINE Operating Instructions Manual

Installation machine
Table of Contents

Advertisement

6.1.1 0_ERROR

Error mode of the system. Open all circuit breakers and remove all driving and charging releases.
The system can only be restarted by rebooting the system. The corresponding error message is
communicated via CAN.

6.1.2 1_INIT

Initialization of all battery components. As soon as all components are initialized, the BMS
automatically switches to the ON mode

6.1.3 2_ON

Battery is in active state
Balancing is not active
Service specification is not active
When the charger is connected, the system automatically switches to CHARGE mode. If no
charger is active, the system automatically switches to DRIVE mode.

6.1.4 3_SHUTDOWN

shutting down the system
Battery is not active

6.1.5 4_CHARGE

Condition for charging the battery
Charge control of the system with charger via the BMS, if a CAN-compatible charger is
used
Balancing is controlled according to the charging algorithm
Power input active
Circuit breaker closed
Acoustic signal transmitter not active
Via the corresponding CAN control signals it is possible to switch to ON, ERROR or DRIVE mode
as soon as the charger is disconnected.
In the event of a fatal fault, the system switches to ERROR mode and the circuit-breaker is opened.

6.1.6 5_DRIVE

Driving status of the battery
Balancing active during longer periods of rest
Power input active
Circuit breaker closed
Acoustic signal generator active based on current performance
Via the corresponding CAN control signals it is possible to switch to ON, ERROR or CHARGE
mode. If the charger is connected and recognized by the BMS, the charger automatically
switches to CHARGE mode.
In the event of a fatal fault, the system switches to ERROR mode and the circuit-breaker is opened.
6.2
DETAILED DESCRIPTION PROPERTIES

6.2.1 Charging behavior with CAN-compatible charger

Controlled charging is only possible with a CAN-compatible charger approved by Probst GmbH.
As soon as the charger plug is connected to the vehicle, the battery system goes into charging
mode and automatically starts the charging process, provided that the wiring of the charger
13