Maintenance and care
7.1.2

Electrics

Service interval
After 25 operating hours
All 50 operating hours
Opening the control cabinet and replacing the fuses (48 V) must ONLY be carried out by an authorised
electrician.
Likewise, all work on the electrical system (rechargeable batteries, batteries, cables, components, etc.),
especially on the 400V power socket, must ONLY be carried out by an authorised electrician! I'M GONNA
KILL YOU!!!
The fuses in the switch cabinet are (partly) NOT
conventional fuses from the passenger car sector,
but special 48 V fuses.
This must be observed when replacing fuses!
51500024
Maintenance work
Control all electrical connections and/or retighten (the implementation is only
allowed by an expert)
Check all fuses (if existing)
Check the electric cabling for breaks and abrasion, if necessary replace it (only
qualified personal)
V2