Scale Error Reporting - Datalogic Magellan 8300 Technical Manual

Hide thumbs Also See for Magellan 8300:
Table of Contents

Advertisement

Scale Error Reporting

Remote
Scale Status
Display
Flash, pause, 1 blink,
E _1
long pause, repeat
sequence.
Flash, pause, 2
E__2
blinks, long pause,
repeat sequence.
Flash, pause, 3
E__3
blinks, long pause,
repeat sequence.
Flash, pause, 4
E__4
blinks, long pause,
repeat sequence.
Flash, pause, 5
E__5
blinks, long pause,
repeat sequence.
3-6
Scale diagnostics uses the Remote Scale Display and the Zero Status lamp
to communicate specific scale failures. The following chart shows the
Remote Display messages, the Scale Status lamp indication, the problem
that the scale is experiencing and what action should be taken. When
troubleshooting, always remember to check all cable connections first
before proceeding with other problem isolation steps.
Lamp
Too much motion at power-
up.
Calibration lost.
Scale communication lost.
Internal scanner/scale prob-
lem.
Scale module failure.
Internal software fault.
Other Scale Reporting
Problem
Description
Check for stable installation. Change
scale motion filter using the labels
found in
lem persists, scale may require calibra-
tion.
Call technical support personnel. Re-
calibrate; restart; recertify (if required).
Call technical support personnel;
report error.
Call technical support personnel;
report error.
Call technical support personnel;
report error.
Action Required
Chapter
5; restart. If prob-
®
Magellan
8300/8400

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magellan 8400

Table of Contents