16 Technical data

In this chapter

16.1 Piping diagram: Outdoor unit

7.0 CuT
7.0 CuT
7.0 CuT
7.0 CuT
7.0 CuT
7.0 CuT
S1PH
k
ERGA04~08EAV3(A) + EHVH04+08SU18+23EA6V
Daikin Altherma 3 R F
4P629090-1 – 2020.08
A subset of the latest technical data is available on the regional Daikin website
(publicly accessible). The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
16.1
Piping diagram: Outdoor unit................................................................................................................................................. 249
16.2
Piping diagram: Indoor unit.................................................................................................................................................... 251
16.3
Wiring diagram: Outdoor unit ................................................................................................................................................ 252
16.4
Wiring diagram: Indoor unit ................................................................................................................................................... 254
16.5
Table 1 – Maximum refrigerant charge allowed in a room: indoor unit............................................................................... 260
16.6
Table 2 – Minimum floor area: indoor unit............................................................................................................................ 261
16.7
Table 3 – Minimum venting opening area for natural ventilation: indoor unit .................................................................... 261
16.8
ESP curve: Indoor unit ............................................................................................................................................................ 263
16.9
Technical specifications: Domestic hot water tank ............................................................................................................... 263
16.9.1
Test results in accordance with EN12897 (2016).................................................................................................. 263
16.9.2
Warning label ......................................................................................................................................................... 264
h
M1F
12.7 CuT
12.7 CuT
Y1S
R3T
9.5 CuT
M1C
a Field piping (liquid: Ø6.4 mm
flare connection)
b Field piping (gas: Ø15.9 mm
flare connection)
c Stop valve (liquid)
d Stop valve with service port
(gas)
R2T
g
4.0 CuT
g
4.0 CuT
g
4.0 CuT
k
12.7 CuT
j
i
16
Technical data
|
R1T
6.4 CuT
6.4 CuT
f
Y1E
e
6.4 CuT
15.9 CuT
d
M1C Compressor
M1F Fan
R1T Thermistor (outdoor air)
R2T Thermistor (heat exchanger)
c
a
6.4 CuT
b
15.9 CuT
3D110394
Installer reference guide
249