Daikin Altherma 3 R F Installer's Reference Manual page 113

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

ERGA04~08EAV3(A) + EHVH04+08SU18+23EA6V
Daikin Altherma 3 R F
4P629090-1 – 2020.08
Item
Human Comfort Interface
WLAN adapter module
LAN adapter
LAN adapter – System requirements
The requirements posed on the system depend on the LAN adapter application/
system layout (app control, or Smart Grid application).
App control:
Smart Grid application:
Item
LAN adapter software
Unit control method
Domestic hot water
settings
Power consumption
control settings
Description
See:
Installation and operation manual of the
Human Comfort Interface
Addendum book for optional equipment
Wires: 2×(0.75~1.25 mm²)
Maximum length: 500 m
[2.9] Control
[1.6] Room sensor offset
See:
Installation manual of the WLAN adapter
module
Addendum book for optional equipment
Use the cable delivered with the WLAN
adapter module.
[D] Wireless gateway
See:
Installation manual of the LAN adapter
Addendum book for optional equipment
Wires: 2×(0.75~1.25 mm²). Must be
sheathed.
Maximum length: 200 m
See below ("LAN adapter – System
requirements").
Requirement
It is recommended to ALWAYS keep the LAN adapter
software up-to-date.
On the user interface, make sure to set [2.9]=2
(Control = Room thermostat)
To allow for energy buffering in the domestic hot
water tank, on the user interface, make sure to set
[9.2.1]=4 (Domestic hot water = Integrated).
On the user interface, make sure to set:
[9.9.1]=1 (Power
Continuous)
[9.9.2]=1 (Type = kW)
9
Electrical installation
|
consumption
control =
Installer reference guide
113