Esp Curve: Indoor Unit; Technical Specifications: Domestic Hot Water Tank; Test Results In Accordance With En12897 (2016) - Daikin Altherma 3 R F Installer's Reference Manual

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

16.8 ESP curve: Indoor unit

16.9 Technical specifications: Domestic hot water tank

16.9.1 Test results in accordance with EN12897 (2016)

ERGA04~08EAV3(A) + EHVH04+08SU18+23EA6V
Daikin Altherma 3 R F
4P629090-1 – 2020.08
Note: A flow error will occur when the minimum water flow rate is not reached.
A (kPa)
120
110
100
90
80
70
60
50
40
30
20
10
0
0
5
10
15
A External static pressure in the space heating/cooling circuit
B Water flow rate through the unit in the space heating/cooling circuit
C Operation range
Dashed lines: Operation area is extended to lower flow rates only in case the unit
operates with heat pump only. (Not in startup, no backup heater operation, no
defrost operation.)
Notes:
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specifications.
Water quality must be according to EU directive 98/83 EC.
INFORMATION
This unit has been tested and approved according to BS EN12897:2016
Description
EHVH04SU18EA6V
EHVH04SU23EA6V
EHVH08SU18EA6V
EHVH08SU23EA6V
C
20
25
30
35
40
45
Hot water capacity
145 l
195 l
145 l
195 l
16
Technical data
|
50
55
60
65
B (l/min)
4D120998
Reheat time
15 min 26 sec
20 min 06 sec
15 min 26 sec
20 min 06 sec
Installer reference guide
263

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents