10
|
Configuration
Disable protections
Forced defrost
Overview field settings
Export MMI settings
Installer reference guide
208
#
Code
[9.F]
[E‑08]
INFORMATION
Protective functions – "Installer-on-site mode". The software is equipped with
protective functions, such as room antifrost. The unit automatically runs these
functions when necessary.
During installation or service this behaviour is undesired. Therefore, the protective
functions can be disabled:
At first power-on: The protective functions are disabled by default. After 36  h
they will be automatically enabled.
Afterwards: An installer can manually disable the protective functions by setting
[9.G]: Disable protections=Yes. After his work is done, he can enable the
protective functions by setting [9.G]: Disable protections=No.
#
Code
[9.G]
N/A
Forced defrost
Manually start a defrost operation.
#
Code
[9.H]
N/A
NOTICE
Forced defrost start-up. You can only start forced defrost when the heating
operation has been running for a while.
All settings can be done using the menu structure. If for any reason it is required to
change a setting using the overview settings, then the overview settings can be
accessed in the field settings overview [9.I]. See
4
setting" [
 133].
About exporting the configuration settings
Export the configuration settings of the unit to a USB memory stick, via the MMI
(the user interface of the indoor unit). When troubleshooting, these settings can
be provided to our Service department.
Description
Power saving function for outdoor unit:
0: No
1: Yes
Description
Disable protections:
0: No
1: Yes
Description
Do you want to start a defrost operation?
Back
OK
ERGA04~08EAV3(A) + EHVH04+08SU18+23EA6V
"To modify an overview
Daikin Altherma 3 R F
4P629090-1 – 2020.08