7. Route the 30-foot shielded cable (supplied with the reset switch kit) from the reset switch
through the conduit box(es) into the XL LED Remote Display housing.
8. Connect the shielded cable wires to the reset switch inside its conduit box and to
terminals 12 and 13 on the J2 terminal block on the XL LED Remote Display PCB.
9. Route the shielded cable (supplied with the XL LED Remote Display) out of the display
housing and through the conduit box(es).
10. Replace the rear panel of the display. See
11. Install and wire the calibrated pulse output device according to the instructions in the
sections above.
Secure Cable and Tighten Cover Upon Reassembly
LectroCount XL LED Remote Displays are assembled and shipped ready for final cable
termination. If the pre-installed shielded cable is removed during installation, be sure to
secure the cable and tighten the cover so the vapor seal is maintained. See
Specifications
.
28
Decimal Place Jumper Setting - Model E1616
The decimal place setting of model E1616 LectroCount XL LED Remote Displays is
determined by the position of jumpers on the J3 and J4 terminals on the PCB. The terminals
are located on the bottom of the PCB on the left side.
The decimal place displayed on Model E1615 coincides with the LectroCount LCR-II/LCR
600 decimal place setting and does not require positioning of the jumpers.
To set the decimal place of Model E1616 LectroCount XL LED Remote Displays:
1. Remove the rear panel of the display.
2. Slide the J3 and J4 jumpers over the terminal pins in the desired position. see table
below.
Get the latest PDF manual:
Mobile/online version of this manual:
For Model E1616 Only
https://www.lcmeter.com/resources/technical/manuals
https://www.lcmeter.com/manuals
Torque Specifications
XL LED Remote Display
.
28
Torque
26

Advertisement

loading

Related Products for LC E1615

This manual is also suitable for:

E1616