Refer to the figure below and follow these steps to wire the LectroCount XL LED Remote
Display model E1615 to a 840404, 84040, or 81920 CPU board:
1. Install Reset Switch Kit.
2. Set the junction box.
3. Route the shielded cable, the pulser wires, and the wires from the external power source
into the junction box. Use the appropriate connectors.
4. Connect the shielded cable wires to the following pulser and external power source wires:
• XL LED terminal 53 (red wire) to Pulser power (red wire) to External Power Source
voltage (+Vo)
• XL LED terminal 54 (white wire) to Pulser signal (black/orange wire)
• XL LED terminal 55 (green wire) to Pulser signal (black/orange wire)
• XL LED terminal 56 (black wire) to Pulser ground (white wire) to External Power Source
ground
5. Tighten connectors and close the boxes.