5. Screw the push button into the conduit box and connect the push button wires to the cable
wires.
6. Connect the 30-foot shielded cable's red wire to terminal 35 and black wire to terminal 38
on the J8 terminal block on the LectroCount CPU board.
Secure Cable and Tighten Cover Upon Reassembly
LectroCount XL LED Remote Displays are assembled and shipped ready for final cable
termination. If the pre-installed shielded cable is removed during installation, be sure to
secure the cable and tighten the cover so the vapor seal is maintained. See
Specifications
.
28
Wiring the Reset Switch Kit (PN 82592) - Models E1617 & E1618
The Reset Switch Kit (P. N. 82592) is required for the installation of XL LED Remote Display
models E1617 and E1618. The reset switch resets the XL LED Remote Display to zero
between deliveries.
Get the latest PDF manual:
Mobile/online version of this manual:
https://www.lcmeter.com/resources/technical/manuals
https://www.lcmeter.com/manuals