Refer to the figure below and follow these steps to wire the LectroCount XL LED Remote
Display model E1615 to a 840404, 84040, or 81920 CPU board:
1. Open the LectroCount register. Refer to the specific LectroCount Register Manual for
specific instructions regarding opening, closing, and sealing the electronic register.
2. Attach a cable gland to a port on the LectroCount electronic register.
3. Route the shielded cable through the cable gland and into the LectroCount register
housing.
4. Connect the four wires of the shielded cable to these terminals on the J12 terminal block
on the LectroCount CPU board:
• XL LED terminal 53 (red wire) to LCR-II/600 terminal 45
• XL LED terminal 54 (white wire) to LCR-II/600 terminal 39
• XL LED terminal 55 (green wire) to LCR-II/600 terminal 40
• XL LED terminal 56 (black wire) to LCR-II/600 terminal 41
5. Tighten the cable gland and close the LectroCount register.