Wiring for Model E1618 - LCMag™
Model E1618 of the LectroCount XL LED Remote Display will accept the calibrated pulse
output of the LCMag HML210 converter.
Since the HML210 does not have an output signal to reset the LED Remote Display, a Reset
Switch Kit (PN 82592) is required for this application. The Reset Switch Kit resets the XL LED
Remote Display to zero between deliveries.
Refer to the figure below and follow these steps to wire the LectroCount XL LED Remote
Display model E1618 to the HM L210 Converter:
1. Install Reset Switch Kit.
2. Open the LCMag HML210 converter. Refer to manual IEM200-10 for specific instructions
regarding opening, closing, and sealing the converter.
3. Route the shielded cable through a cable gland and into the HML210 housing.
4. Connect the shielded cable wire to the designated terminals on the HML210 CPU board:
• XL LED terminal 53 (red wire) to LCR-II/600 terminal 45
• XL LED terminal 54 (white wire) to LCR-II/600 terminal 39
• XL LED terminal 55 (green wire) to LCR-II/600 terminal 40
• XL LED terminal 56 (black wire) to LCR-II/600 terminal 41
5. Tighten the cable gland and close the HML210 converter.