Download Print this page

LC E1615 Parts & Installation Instructions page 22

Advertisement

Secure cable and tighten cover upon reassembly
LectroCount XL LED Remote Displays ship ready for final cable termination. If the pre-
installed shielded cable is removed during installation, be sure to secure the cable and
tighten the cover so the vapor seal remains intact.
Refer to the figure below and follow these steps to install the dual display kit:
1. Remove the rear panel from one LectroCount XL LED Remote Display.
2. Remove the cable wires from the J1 terminal block on the PCB.
3. Remove the cord grip and cable from the port on the bottom of the unit.
4. Attach the 4-port conduit box to the empty port on the bottom of the unit.
5. Attach the cord grips to the 4-port conduit box.
6. Route the shielded cable from the second LectroCount XL LED Remote Display through
one of the cord grips on the 4-port conduit box.
7. Route the shielded cable from the first LectroCount XL LED Remote Display through the
other cord grip on the 4- port conduit box.
8. Connect the wires from both shielded cables to the J1 terminal block on the PCB of the
first LectroCount XL LED Remote Display.
9. Replace the rear panel of the display.
10.Connect the cable wires from the first LectroCount XL LED Remote Display to the
LectroCount electronic register CPU board.