Wiring for Model E1618 - Single Channel Pulsers
Model E1618 of the LectroCount XL LED Remote Display is designed to receive a calibrated
single channel pulse output. A common application of Model E1618 is with a 100 pulses per
revolution solid state single channel pulser (PN 07525) mounted onto a mechanical register
using mounting kit (PN 42695). The E1618 is also compatible with any single channel pulser
that meets the required specifications listed below.
Since single channel pulsers do not have an output signal to reset the LED Remote Display, a
Reset Switch Kit (PN 82592) is required for this application. The Reset Switch Kit resets the XL
LED Remote Display to zero between deliveries. To complete the installation, the installer must
provide a 5 to 28 VDC external power source and a junction box.
Refer to the figure below and follow these steps to wire the LectroCount XL LED Remote
Display model E1618 to a single channel pulser:
1. Install Reset Switch Kit.
2. Set the junction box.
3. Route the shielded cable, the pulser wires, and the wires from the external power source
into the junction box. Use the appropriate connectors.
4. Connect the shielded cable wires to the following pulser and external power source wires:
• XL LED terminal 53 (red wire) to Pulser power (red wire) to External Power Source
voltage (+Vo)
• XL LED terminal 54 (white wire) to Pulser signal
• XL LED terminal 56 (black wire) to Pulser ground (white wire) to External Power Source
ground
5. Tighten connectors and close the boxes.