Download Print this page

LC E1615 Parts & Installation Instructions page 16

Advertisement

5. Tighten the cable gland and close the LectroCount register.
Wiring for Model E1617
Model E1617 of the LectroCount XL LED Remote Display is designed to receive a calibrated
(50 pulses per revolution) solid state quadrature pulse output. Typically, Model E1617 operates
in conjunction with a solid state quadrature pulser (PN 077733) mounted onto a mechanical
register using mounting kit (PN 47824).
Since quadrature pulsers do not have an output signal to reset the LED Remote Display, a
Reset Switch Kit (PN 82592) is required for this application. The Reset Switch Kit resets the XL
LED Remote Display to zero between deliveries. To complete the installation, the installer must
provide a 12 VDC external power source and a junction box.
If the power to the LectroCount LCR-II or LCR 600 exceeds 24 VDC, then the remote
display should be powered from Pin 32 on J8, 5 VDC.
Reversing the Display Counter Direction
Quadrature pulse outputs can send a signal to the display to count in either direction–either
up or down. If the display is counting in the wrong direction, switch the connections of signal
wires from the pulser (black and orange for PN 077733) to the display (J1 terminals 54 and
55) to reverse the counter direction.