Master Comp - Roland TM-6 PRO Data List

Trigger module
Hide thumbs Also See for TM-6 PRO:
Table of Contents

Advertisement

SEND ([F2] button)
Parameter
[F3] button
PAD1<HEAD>–PAD6<RIM>

MASTER COMP

This is a two-band equalizer that is provided for each kit.
The sound processed by the master compressor is output from the MASTER OUT jacks and the PHONES jack.
* If the Master Direct Sw is set to "DIRECT" in OUTPUT SETUP (p. 17), the master compressor effect is not applied to the sound that is output from the MASTER OUT jacks.
Parameter
[F3] button
[F2] button
TEMPLATE
Split Freq
DETAIL ([F2] button)
Parameter
Thrshd*1
Gain*1
Atk*1
Rls*1
Ratio*1
Knee*1
[F1] (LO) button*2
[F2] (HI) button*2
[F3] (MONITOR) button*2
*1 If Split Freq is set to something other than "SINGLE, " the low band and high band can be set independently.
*2 Only if Split Freq is set to something other than "SINGLE"
Value
OFF, REV ON
-INF–+6.0dB
Value
OFF, COMP ON
SINGLE SOFT COMP, SINGLE HARD
COMP, SINGLE LIMITER, 2 BAND SOFT
COMP, 2 BAND HARD COMP, 2 BAND
LIMITER
SINGLE, 10–16000Hz
Value
-48–0dB
-24–+24dB
0.1–100mSec
10–1000mSec
1:1–100:1
HARD, SOFT1–3
Explanation
Turns reverb on/off.
Amount of reverb applied for each drum trigger
MEMO
If you press the [F1] (H&R) button to turn it "ON, " you can simultaneously make settings for the head
area and rim area.
Explanation
Turns master comp on/off.
Allows you to make detailed settings for the master compressor.
Character of the compressor
* When you change this parameter, all parameters of the master compressor change to optimal
settings for your selection. You can then make further adjustments to these parameters as
necessary. Depending on the settings of these parameters, the resulting effect might not match
the TEMPLATE setting.
Bandwidth of the compressor
If this is "SINGLE, " the master compressor operates as a single-band compressor that is used only on
the high band.
Explanation
Volume level at which compression begins
Output level of the compressor
Time from when the volume goes up the threshold level until the compressor effect applies
Time from when the volume falls below the threshold level until the compressor effect no longer
applies
Compression ratio
Attack of the sound at the moment compression is applied
Switch the parameter display between the high-frequency and low-frequency bands when the
effect is operating as a two-band compressor.
Allows you to individually audition the frequency band (low or high) currently selected in the tab
when the effect is operating as a two-band compressor.
* These settings are reset if you perform any of the following operations.
5 Respecify the Type parameter as single band compressor
5 Set the Split Freq parameter to "SINGLE"
5 Exit the MASTER COMP screen
MENU