5 Installation Procedure
Use only a MECHATROLINK-III dedicated communication cable. Refer to
more information.
Note:
Maximum transmission distance is 100 m (328 ft). Minimum wiring distance between stations is 0.2 m (7.9 in).

Option Connection Diagram

*1
Connect the MECHATROLINK-III cable to connector CN1 or CN2.
*2
Connect the provided ground wire for installations on 1000-series drives and GA500 drives.
The ground wire is not necessary for installation on GA700, GA800, CR700, or CH700 drives.

Communication Cable Topology

The dual communication cable ports on the option board act as a switch to allow for
flexibility in cabling topology. Users may employ a traditional star network topology
using a single communication cable port on the option. Users may also choose to employ
a ring topology using both communication cable ports on the option and reduce the
requirements of MECHATROLINK-III hub module ports.
28
Figure 5.14 Option Connection Diagram
YASKAWA TOEP C730600 88A MECHATROLINK-III Installation Manual